Views: 0 Author: Site Editor Publish Time: 2023-09-04 Origin: Site
In the current energy supply trend, environmental protection requirements continue to improve the situation, people continue to seek both energy saving and environmental protection of new energy, and air source heat pumps should be born. Air source heat pumps can use the heat in the air to achieve the effect of heating, do not emit harmful substances, and will not cause secondary pollution. Air source heat pump units are generally installed in the open field, if the installation position is blocked and not ventilated, then it will affect the effect of the operation. The following details the pool's special air source heat pump installation method and other matters.
Here is the content list:
Installation standard
External environment
The normal use of a DC inverter swimming pool heat pump unit meets the following three elements: unobtainable fresh air, in line with the power supply of the unit, and line with the circulation flow of the unit. Air source heat pump units should be installed in outdoor ventilation and easy maintenance places, can not be installed in narrow air-poor spaces. At the same time, the unit should keep a certain distance from the surrounding area to keep the air unimpeded, and the miscellaneous pile should not be placed in the position of the unit in and out of the wind, so as not to reduce the heating efficiency of the unit. The unit can be arranged on the roof or near the ground of the building using the equipment and should be far away from the densely populated place, to prevent the unit from running airflow and noise impact on the environment. When the unit is a side air inlet, the distance between the air inlet surface and the wall is not less than 1 meter. When the gold cover of the two units is arranged relatively, the distance is not less than 1.5 meters. Unit for the top of the air structure, the outlet of the headroom is not less than 2 meters. Only one side of the partition wall around the unit is allowed to be higher than the unit height. The base height of the unit should be no less than 300mm and greater than the local snow thickness. The unit installation shall be provided with measures to eliminate a large amount of condensate water generated by the unit.
Control the relative humidity well to avoid condensation. Because the indoor temperature of the pool area is generally 28 degrees, the relative humidity is more than 60% of RH. According to pool design standards, indoor moisture content can not be greater than 14g/kg, which is equivalent to the dew point temperature is not more than 20 degrees, so control the relative humidity of the environment around the DC inverter swimming pool heat pump to ensure indoor humidity.
Linuo Ritter International Co., Ltd has several laboratories and certificates, which are authorized by professional testing third parties, and the test report can be approved by them. Use technical laboratory to test products, control product quality, and provide the best service for customers.